  • Style STRI
    • INCOLOY Sheath
    • 225 - 2,400 Watts
    • 120 and 240 Volt
    • 4 - 30 W/In2
    • 1600°F (870° C) Maximum Sheath Temperature
  • Style STRS
    • Steel Sheath
    • 150 - 2,725 Watts
    • 120 and 240 Volt
    • 3 - 20 W/In2
    • 750°F (450°C) Maximum Sheath Temperature

Descripción

The STRI and STRS series have been discontinued. Please contact our Temperature Engineering department for a viable replacement.

Syle STRI
APPLICATIONS
Molds and other heat-transferring metal parts and air heating applications. Immersion heating with flange, screwplug, threaded fitting or other means of mounting.

ADVANTAGES
Elements with both terminals at one end, in dies, can simplify wiring in many cases. Use slim elements to concentrate heat into a confined area, taking up less space than a U-shaped element with terminals at each end.

.315" (8 mm) Diameter Round Cross-Section Single-End Terminal



Watts Volts W/In2 Dimensions in (cm) INCOLOY Sheath
Model No.
Weight
(Lb.)
Sheath A Heated B
2251203011 7/8 (30)7 1/8 (18)STRI-1248/120V0.4
3251203015 7/8 (40)11 1/8 (28)STRI-1648/120V0.4
3252403015 7/8 (40)11 1/8 (28)STRI-1648/240V0.4
4501203019 7/8 (50)15 1/8 (38)STRI-2048/120V0.4
4502403019 7/8 (50)15 1/8 (38)STRI-2048/240V0.4
5751203023 7/8 (60)19 1/8 (49)STRI-2448/120V0.4
5752403023 7/8 (60)19 1/8 (49)STRI-2448/240V0.4
7001203027 7/8 (70)23 1/8 (59)STRI-2848/120V0.8
7002403027 7/8 (70)23 1/8 (59)STRI-2848/240V0.8
8001203031 7/8 (80)27 1/8 (69)STRI-3248/120V0.8
8002403031 7/8 (80)27 1/8 (69)STRI-3248/240V0.8
9251203035 7/8 (91)31 1/8 (79)STRI-3648/120V0.8
9252403035 7/8 (91)31 1/8 (79)STRI-3648/240V0.8
1,0501203039 7/8 (101)35 1/8 (89)STRI-4048/120V1
1,0502403039 7/8 (101)35 1/8 (89)STRI-4048/240V1
1,1751203043 7/8 (111)39 1/8 (99)STRI-4448/120V1
1,1752403043 7/8 (111)39 1/8 (99)STRI-4448/240V1
1,2001202847 7/8 (122)43 1/8 (110)STRI-4848/120V1
1,2752403047 7/8 (122)43 1/8 (110)STRI-4848/240V1
1,2001202651 7/8 (132)47 1/8 (120)STRI-5248/120V1.3
1,4002403051 7/8 (132)47 1/8 (120)STRI-5248/240V1.3
1,1501202355 7/8 (142)51 1/8 (130)STRI-5648/120V1.3
1,5252403055 7/8 (142)51 1/8 (130)STRI-5648/240V1.3
1,07512013.759 7/8 (152)55 1/8 (140)STRI-6048/120V1.3
1,6502403059 7/8 (152)55 1/8 (140)STRI-6048/240V1.3
8751201371 7/8 (183)67 1/8 (171)STRI-7248/120V1.3
2,0002403071 7/8 (183)67 1/8 (171)STRI-7248/240V1.3
7501201083 7/8 (213)79 1/8 (201)STRI-8448/120V1.8
2,3502403083 7/8 (213)79 1/8 (201)STRI-8448/240V1.8
650120795 7/8 (243)91 1/8 (231)STRI-9648/120V1.8
2,4002402795 7/8 (243)91 1/8 (231)STRI-9648/240V1.8
5751206107 7/8 (274)103 1/8 (262)STRI-10848/120V2.5
2,30024023107 7/8 (274)103 1/8 (262)STRI-10848/240V2.5
5001204119 7/8 (304)115 1/8 (292)STRI-12048/120V2.5
2,00024018119 7/8 (304)115 1/8 (292)STRI-12048/240V2.5


.475 Diameter (1.2cm) Round Cross-Section Single-Ended Terminals


Watts Volts W/In2 Dimensions in (cm) INCOLOY Sheath
Model No.
Weight
(Lb.)
Sheath A Heated B
3251203011 7/8 (30)7 3/16 (18)STRI-1245/1200.5
5001203015 7/8 (40)11 3/16 (28)STRI-1645/1200.5
5002403015 7/8 (40)11 3/16 (28)STRI-1645/2400.5
6751203019 7/8 (50)15 3/16 (39)STRI-2045/1200.5
6752403019 7/8 (50)15 3/16 (39)STRI-2045/2400.5
8501203023 7/8 (60)19 3/16 (49)STRI-2445/1200.5
8502403023 7/8 (60)19 3/16 (49)STRI-2445/2400.5
10251203027 7/8 (70)23 3/16 (59)STRI-2845/1201
10252403027 7/8 (70)23 3/16 (59)STRI-2845/2401
12251203031 7/8 (80)27 3/16 (69)STRI-3245/1201
12252403031 7/8 (80)27 3/16 (69)STRI-3245/2401
14001203035 7/8 (91)31 3/16 (79)STRI-3645/1201
14002403035 7/8 (91)31 3/16 (79)STRI-3645/2401
15751203039 7/8 (101)35 3/16 (89)STRI-4045/1201.3
15752403039 7/8 (101)35 3/16 (89)STRI-4045/2401.3
17501203043 7/8 (111)39 3/16 (100)STRI-4445/1201.3
17502403043 7/8 (111)39 3/16 (100)STRI-4445/2401.3
15751202547 7/8 (122)43 3/16 (110)STRI-4845/1201.3
19252403047 7/8 (122)43 3/16 (110)STRI-4845/2401.3
14501202151 7/8 (132)47 3/16 (120)STRI-5245/1201.8
21002403051 7/8 (132)47 3/16 (120)STRI-5245/2401.8
13251201755 7/8 (142)51 3/16 (130)STRI-5645/1201.8
22752403055 7/8 (142)51 3/16 (130)STRI-5645/2401.8
12251201559 7/8 (152)55 3/16 (140)STRI-6045/1201.8
24752403059 7/8 (152)55 3/16 (140)STRI-6045/2401.8
10001201071 7/8 (183)67 3/16 (171)STRI-7245/1201.8
30002403071 7/8 (183)67 3/16 (171)STRI-7245/2401.8
850120783 7/8 (231)79 3/16 (201)STRI-8445/1202.3
34002402983 7/8 (213)79 3/16 (201)STRI-8445/2402.3
750120695 7/8 (243)91 3/16 (231)STRI-9645/1203.3
30002402295 7/8 (243)91 3/16 (231)STRI-9645/2403.3
6501204107 7/8 (274)103 3/16 (261)STRI-10845/1203.3
260024017107 7/8 (274)103 3/16 (261)STRI-10845/2403.3
5751203119 7/8 (304)115 3/16 (292)STRI-12045/1203.3
230024013119 7/8 (304)115 3/16 (292)STRI-12045/2403.3


Syle STRS
APPLICATIONS
Molds and other heat-transferring metal parts and air heating applications. Immersion heating with flange, screwplug, threaded fitting or other means of mounting.

ADVANTAGES
Elements with both terminals at one end, in dies, can simplify wiring in many cases. Use slim elements to concentrate heat into a confined area, taking up less space than a U-shaped element with terminals at each end.

.315" (8 mm) Diameter Round Cross-Section Single-End Terminal



Watts Volts W/In2 Dimensions in (cm) Steel Sheath
Model No.
Weight
(Lb.)
Sheath A Heated B
1501202011 7/8 (30)71/8 (18)STRS-1248/120V0.4
2251202015 7/8 (40)11 1/8 (28)STRS-1648/120V0.4
2252402015 7/8 (40)11 1/8 (28)STRS-1648/240V0.4
3001202019 7/8 (50)15 1/8 (38)STRS-2048/120V0.4
3002402019 7/8 (50)15 1/8 (38)STRS-2048/240V0.4
3751202023 7/8 (60)19 1/8 (49)STRS-2448/120V0.4
3752402023 7/8 (60)19 1/8 (49)STRS-2448/240V0.4
4501202027 7/8 (70)23 1/8 (59)STRS-2848/120V0.8
4502402027 7/8 (70)23 1/8 (59)STRS-2848/240V0.8
5501202031 7/8 (80)27 1/8 (69)STRS-3248/120V0.8
5502402031 7/8 (80)27 1/8 (69)STRS-3248/240V0.8
6251202035 7/8 (91)31 1/8 (79)STRS-3648/120V0.8
6252402035 7/8 (91)31 1/8 (79)STRS-3648/240V0.8
7001202039 7/8 (101)35 1/8 (89)STRS-4048/120V1
7002402039 7/8 (101)35 1/8 (89)STRS-4048/240V1
7751202043 7/8 (111)39 1/8 (99)STRS-4448/120V1
7752402043 7/8 (111)39 1/8 (99)STRS-4448/240V1
8501202047 7/8 (122)43 1/8 (110)STRS-4848/120V1
8502402047 7/8 (122)43 1/8 (110)STRS-4848/240V1
9251202051 7/8 (132)47 1/8 (120)STRS-5248/120V1.3
9252402051 7/8 (132)47 1/8 (120)STRS-5248/240V1.3
10251202055 7/8 (142)51 1/8 (130)STRS-5648/120V1.3
10252402055 7/8 (142)51 1/8 (130)STRS-5648/240V1.3
107512019.759 7/8 (152)55 1/8 (140)STRS-6048/120V1.3
11002402059 7/8 (152)55 1/8 (140)STRS-6048/240V1.3
8751201371 7/8 (183)67 1/8 (171)STRS-7248/120V1.3
13252402071 7/8 (183)67 1/8 (171)STRS-7248/240V1.3
7501201083 7/8 (213)79 1/8 (201)STRS-8448/120V1.8
15752402083 7/8 (213)79 1/8 (201)STRS-8448/240V1.8
650120795 7/8 (243)91 1/8 (231)STRS-9648/120V1.8
18002402095 7/8 (243)91 1/8 (231)STRS-9648/240V1.8
5751206107 7/8 (274)103 1/8 (262)STRS-10848/120V2.5
205024020107 7/8 (274)103 1/8 (262)STRS-10848/240V2.5
5001204119 7/8 (304)115 1/8 (292)STRS-12048/120V2.5
200024013119 7/8 (304)115 1/8 (292)STRS-12048/240V2.5

.475" (12 mm) Diameter Round Cross-Section Single-End Terminal



Watts Volts W/In2 Dimensions in (cm) Steel Sheath
Model No.
Weight
(Lb.)
Sheath A Heated B
2001202011 7/8 (30)7 3/16 (18)STRS-1245/120V0.5
3251202015 7/8 (40)11 3/16 (28)STRS-1645/120V0.5
3252402015 7/8 (40)11 3/16 (28)STRS-1645/240V0.5
4501202019 7/8 (50)15 3/16 (38)STRS-2045/120V0.5
4502402019 7/8 (50)15 3/16 (38)STRS-2045/240V0.5
5751202023 7/8 (60)19 3/16 (49)STRS-2445/120V0.5
5752402023 7/8 (60)19 3/16 (49)STRS-2445/240V0.5
7001202027 7/8 (70)23 3/16 (59)STRS-2845/120V1
7002402027 7/8 (70)23 3/16 (59)STRS-2845/240V1
8001202031 7/8 (80)27 3/16 (69)STRS-3245/120V1
8002402031 7/8 (80)27 3/16 (69)STRS-3245/240V1
9251202035 7/8 (91)31 3/16 (79)STRS-3645/120V1
9252402035 7/8 (91)31 3/16 (79)STRS-3645/240V1
10501202039 7/8 (101)35 3/16 (89)STRS-4045/120V1.3
10502402039 7/8 (101)35 3/16 (89)STRS-4045/240V1.3
11751202043 7/8 (111)39 3/16 (99)STRS-4445/120V1.3
11752402043 7/8 (111)39 3/16 (99)STRS-4445/240V1.3
12751202047 7/8 (122)43 3/16 (110)STRS-4845/120V1.3
12752402047 7/8 (122)43 3/16 (110)STRS-4845/240V1.3
14001202051 7/8 (132)47 3/16 (120)STRS-5245/120V1.8
14002402051 7/8 (132)47 3/16 (120)STRS-5245/240V1.8
13251201755 7/8 (142)51 3/16 (130)STRS-5645/120V1.8
15252402055 7/8 (142)51 3/16 (130)STRS-5645/240V1.8
12251201559 7/8 (152)55 3/16 (140)STRS-6045/120V1.8
16502402059 7/8 (152)55 3/16 (140)STRS-6045/240V1.8
10001201071 7/8 (183)67 3/16 (171)STRS-7245/120V1.8
20002402071 7/8 (183)67 3/16 (171)STRS-7245/240V1.8
850120783 7/8 (231)79 3/16 (201)STRS-8445/120V2.3
23502402083 7/8 (213)79 3/16 (201)STRS-8445/240V2.3
750120695 7/8 (243)91 3/16 (231)STRS-9645/120V3.3
27252402095 7/8 (243)91 3/16 (231)STRS-9645/240V3.3
6501204107 7/8 (274)103 3/16 (262)STRS-10845/120V3.3
260024017107 7/8 (274)103 3/16 (262)STRS-10845/240V3.3
5751203119 7/8 (304)115 3/16 (292)STRS-12045/120V3.3
230024013119 7/8 (304)115 3/16 (292)STRS-12045/240V3.3
If element is to be bent, specify "must be annealed".

Hacer Pedido(Especifique el Número de Modelo)
Número de parte/Desc.
Cant.
RoHS
Descripción
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
Quick Ship
STRI-1248/120V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 225W
Quick Ship
STRI-1645/240V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 500 W
Quick Ship
STRI-1648/120V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 325 W
Quick Ship
STRI-2448/120V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 575 W
Quick Ship
STRI-2448/240V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 575 W
Quick Ship
STRI-3648/120V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 925 W
Quick Ship
STRI-4048/240V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 1050 W
Quick Ship
STRI-4848/240V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 1275 W
Quick Ship
STRS-1248/120V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 150 W
Quick Ship
STRS-1648/120V
Consultar venta  
Disponible en: 
 
RoHS compliant
Single-end terminal, 225 W

Ordenar Por Número de Parte

Número de parte
Cant.
Número de parte
Cant.


Todos los productos en este sitio se muestran en la moneda de EE.UU.
NOTA: When used as an immersion heater, specify “sealed end”.

Generador de Número de Parte

Generador de Número de parte
Descripción de Opciones:


(1) Style seleccionar de:
STRI para style STRI
STRS para style STRS

(2) Shealth A seleccionar de:
12 para 11 7/8 in.
16 para 15 7/8 in.
20 para 19 7/8 in.
24 para 23 7/8 in.
28 para 27 7/8 in.
32 para 31 7/8 in.
36 para 35 7/8 in.
40 para 39 7/8 in.
44 para 43 7/8 in.
48 para 47 7/8 in.
52 para 51 7/8 in.
56 para 55 7/8 in.
60 para 59 7/8 in.
72 para 71 7/8 in.
84 para 83 7/8 in.
96 para 95 7/8 in.
108 para 107 7/8 in.
120 para 119 7/8 in.

(3) Diamter Round Cross-Section Single-End Terminal seleccionar de:
45 para 0.475 in.
48 para 0.315 in.

(4) Voltage seleccionar de:
120V para 120 V
480V para 480 V
NOTA: No todas las combinaciones pueden no ser válidas, compruebe la hoja de especificaciones para números de parte válidos.