10 Point Non-Reversible Temperature Label
Models In Stock
- Ten temperature points per label
- Indicator turns black when exposed
- Actual size: 2.1' x 0.7' (54 x 18 mm)
- Sold in Packs of 10 and 30
TL-10
From
$
22.68
Models In Stock

Product Overview
- Accuracy Detail Up to 99°C (210°F) is ± 1°C (1.8°F); From 100°C (212°F) to 154°C (309°F) is ± 1.5°C (2.7°F); From 160°C (320°F) to 280°C (536°F) is ± 1% and ± 1°C (1.8°F
- Applications Aeronautics and Aerospace, Air and HVAC, Building and Maintenance, General Purpose
- Form factor Strip with 10 Dots in line
- Height 54 mm
- Length 18 mm
- Number of Temperature Points 10
- Response Time 1 sec
- Reversible/Non Reversible Non-Reversible
Applications:
• General • Aeronautical • Electrical • HVAC • Most surface measurements.
SPECIFICATIONS
Accuracy: Up to 99°C (210°F) is ± 1°C (1.8°F);
From 100°C (212°F) to 154°C (309°F) is ± 1.5°C (2.7°F);
From 160°C (320°F) to 280°C (536°F) is ± 1% and ± 1°C (1.8°F)
TL-10 Series Labels, 10-Temperature Range
Read More
Read Less• General • Aeronautical • Electrical • HVAC • Most surface measurements.
SPECIFICATIONS
Accuracy: Up to 99°C (210°F) is ± 1°C (1.8°F);
From 100°C (212°F) to 154°C (309°F) is ± 1.5°C (2.7°F);
From 160°C (320°F) to 280°C (536°F) is ± 1% and ± 1°C (1.8°F)
TL-10 Series Labels, 10-Temperature Range
Model No | Temperature Ratings | ||||||||||||||||||||||
TL-10-105(*) |
| ||||||||||||||||||||||
TL-10-190(*) |
| ||||||||||||||||||||||
TL-10-290(*) |
| ||||||||||||||||||||||
TL-10-390(*) |
|
Show Ratings & Reviews
Rated 5 out of
5
by
211us from
works
Something that works as advertised!!!
Getting the information I had hoped to get.
Date published: 2016-02-14
Rated 5 out of
5
by
Sue2 from
Did the job
These had the temperature range I was looking for, and reasonable increments. Worked just fine on my project.
Date published: 2016-08-25
Rated 5 out of
5
by
et dan from
don't leave for home without this in place
FREIND gave me some so now can't live without so ordering my own
Date published: 2016-04-12
Rated 3 out of
5
by
Glass Man from
Desired tempt range not an option
Works well. Need from 120 to 220 ( or 100 to 200) option
Date published: 2025-03-10
Rated 5 out of
5
by
Amba from
Accurate temperature and easy to use
These Temperature labels are great for us to be able to record accurate temperature on our stainless steel products.
Date published: 2025-01-27
Rated 5 out of
5
by
Nishanth from
Easy to Use Stickers
Good range options and multiple usages at various applications
Date published: 2024-04-09
Rated 5 out of
5
by
Nishanth from
Easy to Use Stickers
Works smoothly and easy to install even in hard to reach places
Date published: 2024-04-09
Rated 5 out of
5
by
dpjokers7 from
Great product and purchasing experience.
This is a great product! The purchasing experience was easy, and my order arrived very fast.
Date published: 2023-12-29
- y_2025, m_3, d_28, h_9
- bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
- cp_1, bvpage1
- co_hasreviews, tv_0, tr_26
- loc_en_US, sid_TL-10-105-10, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
- clientName_omega
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getReviews, 23ms
- REVIEWS, PRODUCT
Hello, referring to an older inquiry: We'd like to use the labels for vaccum applications. Why is this not recommended? Is the reaction mechanism/precision altered or does the glue degas? What is the reaction mechanism of the sensors?
Asked by: Phil74
Hello again, thanks for the fast reply. In order to judge whether there might a deviating response it would be very useful if you could give details on the reaction mechanism, e.g if it requires atmospheric oxygen. Then the response might just be delayed.
Kind regards, Phil
Answered by: Phil74
Date published: 2021-01-17
What is the shelpf life of these tapes if stored in the fridge?
Asked by: NickL59919
Shelf life is one year when stored in a cool dry location.
Answered by: Temperature
Date published: 2025-03-12
Will these labels only measure surface temperature of where its mounted or the air around it too? (conduction/convection). Want to detect max temperature of product going through oven.
Asked by: gbdonhowe
The Temperature Labels are designed to measure the surface temperature of what they are adhered.
Answered by: ApplicationEngineerANB
Date published: 2021-11-19
What is the reaction time for the strip to change color. I want to test an overcurrent event that could be less than a second. The conductor I am using should heat up momentarily and then cool off. is 1 second enough of a contact to change color?
Asked by: Elton P
The response time for the temperature labels is one second so it is not 100% positive that it will react quickly enough for this application.
Answered by: ApplicationEngineerANB
Date published: 2024-01-09
Does the surface to which you apply the label need to be 100% flat? If not, what is the most curved surface these labels can be applied to?
Asked by: gbrawn
The Temperature Labels are flexible and can be attached to a curved surface. The bend radius has not been established but down to a 1/2" should be fine.
Answered by: ApplicationEngineerANB
Date published: 2021-11-09
What's the thickness of the stickers? Webpage and Spec sheets only gives Height and Width. Thanks
Asked by: Miguel B
The approximate thickness of the TL temperature labels is 0.026".
Answered by: ApplicationEngineerANB
Date published: 2023-12-01
can we use it in vacuum chambers. 5e-6 at
Asked by: nirgu
Thank you for your inquiry. Unfortunately these labels are not suitable for vacuum applications.
Answered by: CB Engineer
Date published: 2020-10-23
It seems a strip could be cut into individual dots. Does cutting the strip into separate dots affect temperature indication or have other impact? Does cutting the strip risk leaking of a chemical or other material/liquid?
Asked by: Peter Strzepa
Thank you for your inquiry Peter. Cutting or modifying the strips in any way will permanently damage the strip and it will not longer measure temperature.
Answered by: Application Engineer MC
Date published: 2022-10-21
- y_2025, m_3, d_28, h_9CST
- bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
- cp_1, bvpage1
- co_hasquestionsanswers, tq_10
- loc_en_US, sid_TL-10-105-10, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
- clientName_omega
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getContent, 40ms
- QUESTIONS, PRODUCT