Skip to search Skip to main content Skip to navigation

Call us at 1-888-826-6342

We noticed you are from . Visit your local site for regional offers and live support.
Back To Top

Head Mount Signal Conditioners

15 Products
Thermocouple Input Temperature Transmitter w/ Pushbutton Config

The TX13 head mount transmitter is a 2 wire 4-20mA transmitter for thermocouple inputs. Accepts Type K, J, N, E, T, R, S and mV inputs. Pushbutton range configuration.

Head Mount Temperature Transmitters | FM Approved

The TX91-92 series transmitters are head mount with model specific input for TC & RTD ranges. Metal case, RFI shield 2-wire transmitter with 4-20mA output. Non-isolated

Head Mount Thermocouple Transmitter w/ Process Output

The TX31 is a 2 wire head mount process transmitter that converts thermocouples to process signals. Model specific TC type, loop powered. DIP switch range setting.

Head Mount Temperature Transmitters with RFID Communications

The TX400 series is a head mount transmitter that accepts RTD and thermocouple inputs depending on model and provides 4-20mA output. RFID requires TX400-RFID Programmer.

Communication Tool for TXUN Series and DRST-FR

The TXUN-KIT is a loop link communication kit used to configure TXUN-ST, TXUN-FM, TXUN-HT, and DRST-FR models. Configured with OMSET PC software.

2-Wire Programmable Transmitter with Universal Input

The TXUN-ST-FM Series is a 2-wire programmable head mount transmitter with RTD, TC, Ω, or mV Input. FM approved model available (TXUN-FM). Programmable via TXUN-KIT.

RTD Head Mount Temperature Transmitter w/ User Trim

The TX12 head mount transmitter is a 2 wire 4-20mA transmitter for RTD inputs. User trim allows error null and has pushbutton configuration. LED sensor fail indicator.

Programmable Head Mount Temperature Transmitter for Thermocouples

The TX86 is a universal input for RTD, TC, Ω, POT and mV with 4-20mA output. Field scalable via front panel programmable push buttons. LED display and SSR output.

Miniature Low-Cost Temperature 2-wire Transmitters

The TX91A-92A series are low cost miniature transmitters with inputs for thermocouples and RTDs with 4-20mA output. Non-isolated head mount with upscale break protection.

Miniature Head Mount Temperature Transmitters

The TX93-94-95 series are low profile 19mm design head mountable transmitters with thermocouple, RTD, or voltage input and 4-20mA out. Some models come with TC or RTD probe.

Head Mount R and S type TC Transmitter w/ 4-20mA Output

The TX253 is a 2 wire 4-20mA transmitter with Type R or S type thermocouple inputs. Adjustable span, fits in NB1 protection head. DIP switch multi-range. Non-isolated.

2-Wire Transmitter w/ Hart Protocol Enabled | 2 Analog Inputs

The TXUN-HT dual input accepts RTD, TC, O, and Bipolar mV Input with 2 wire 4-20mA output. Hart 5 or Hart 7 protocol. TXUN-KIT programmer required.

Loop Powered Thermistor Head Mount Transmitter w/ 4-20mA Output

The TX206TH is a 2 wire 4-20mA transmitter with thermistor input. Supports many thermistor types, loop powered, PC configurable range (w/ programmer). Free software.

Field Rangeable Mini 2-wire Transmitters w/ Model Specific Input

Thermocouple, RTD, and mV input models with 4-20mA output. DIP switch selectable type and range. Isolated and non-isolated models available. Loop powered

More Related Items

Head Mount Signal Conditioners

 Head Mount Signal Conditioners are used in a variety of industrial, commercial, and laboratory applications. They are designed to convert and condition electrical signals from a variety of sensors, such as thermocouples, RTDs, Ohms, Potentiometers, and mV signals.

Omega Engineering offers a wide range of Head Mount Signal Conditioners, which can be easily configured and scaled to meet any kind of specification. Our conditioners feature a variety of convenient features such as pushbutton configuration, LED displays, SSR output, and user trim. These sensors are small sized and offered in a variety of input and transmission options.